Hanna Nitrate Checker Instructions, Step by Step
Share
Quick answer
Hanna nitrate checker instructions have three parts: mix your sample with reagents HI781A-0 and HI781B-0 in the mixing vial, filter it into the cuvette and zero the checker, then add reagent HI781C-0, shake for 2 minutes, and read after the 8 minute countdown. These steps are for the Hanna HI781 Marine Nitrate Low Range Checker, from Hanna's 09/20 manual.
| Who | Reef keepers with a Hanna Marine Nitrate Low Range Checker HC, model HI781. |
|---|---|
| What | A colorimetric test for nitrate in seawater, from 0.00 to 5.00 ppm as NO3. A dilution step stretches it to 50.0 ppm. |
| When | On your regular testing day. Reef Builders (2020) says a weekly test is enough once a tank has cycled. |
| Where | At your bench, with dry filter parts and a clean, dry cuvette. Hanna says this checker is not recommended for freshwater. |
| Why | Sources disagree on how low a reef should run, and a reading shows where your tank sits against the range you choose. |
What you need
Hanna lists these items with the HI781: a marine nitrate low range reagent starter kit for 25 tests, two sample cuvettes with caps, 25 filter papers, a filter holder, a mixing vial with cap, a 10 mL syringe, a 5 mL syringe with tip, a 1 mL syringe, a plastic refilling pipette, a 16 gauge blunt needle, a 1.5V AAA battery and the manual.
Prepare the filter holder
Unscrew the two halves of the reusable filter holder. Put one paper filter on the lower piece, on top of the clear colorless gasket. The upper piece is marked TOP and the lower piece has no marking. Thread the upper piece over the lower piece and tighten it. Make sure the paper does not overlap the threads. Hanna says the filter and holder must be dry before use, so the filter does not tear.
Hanna nitrate checker instructions, step by step
- Turn it on. Press ON/OFF. All segments show for a few seconds, then the display shows "Add", "C.1" with "Press" blinking.
- Measure the sample. Use the 10 mL syringe to measure exactly 7 mL of tank water into the large mixing vial.
- Add reagent A. Use the 5 mL syringe to add exactly 4 mL of HI781A-0 reagent to the mixing vial.
- Add reagent B and shake. Add the contents of one packet of HI781B-0 reagent. Replace the cap and shake vigorously for 1 minute.
- Draw it up. Take the cap off the mixing vial. Thread the covered needle onto the 10 mL syringe, remove the plastic cover, and draw up the contents of the vial.
- Filter into the cuvette. Cover the needle, twist it off, then attach the filter holder assembly to the syringe with its threaded connection. Hold it over a cuvette and push the plunger very slowly until the cuvette is filled to the 10 mL mark. Replace the cap.
- Zero the checker. Insert the cuvette and close the cap. Press ON/OFF. When the display shows "Add", "C.2" with "Press" blinking, the checker is zeroed.
- Add reagent C and shake. Remove the cuvette, unscrew the cap, and add the contents of one packet of HI781C-0 reagent. Replace the cap and shake vigorously for 2 minutes.
- Start the countdown. Insert the cuvette and close the cap. Press and hold ON/OFF. The display shows a countdown before the measurement. Or wait 8 minutes and press the button.
- Read. When the timer ends the checker takes the reading and shows nitrate in ppm of NO3. It turns off 10 minutes after the reading.
Filtering should take about 30 seconds. Keep a constant, light pressure on the plunger and do not use extra force.
If your reading is above 5 ppm
For samples with 5 to 50 ppm nitrate, Hanna gives a dilution procedure. Measure 1 mL of tank water with the 1 mL syringe into the mixing vial. Add nitrate and nitrite free artificial seawater up to the 10 mL mark. Cap and mix. Attach the blunt needle to the 10 mL syringe, draw up 7 mL of the diluted sample, and throw out the other 3 mL. Squirt the 7 mL back into the empty vial, then carry on from the reagent A step. Multiply the result by 10.
Hanna warns that dilution lowers accuracy, so measure the volumes with care.
Tips for a better reading
- Keep debris out of the sample.
- The cuvette must be dry outside and free of fingerprints, oil and dirt. Wipe it with a microfiber or lint-free cloth.
- Bubbles raise the reading. Swirl the cuvette or tap it gently to clear them.
- Do not let the reacted sample stand too long after reagent has been added.
- Pour the sample out right after the reading. The glass can stain for good.
- Hanna lists nitrite and copper as interferences.
Zinc powder can build up in the filter holder. Hanna says to unscrew it, pop the small ridged disk out of the upper half, use a bristle brush and detergent if needed, rinse with RODI or tap water, and dry it before use. Our Hanna Nitrate Checker Kit Organizer gives the parts a home between tests.
What the error messages mean
- Light High or Light Low: too much or too little light for a reading. Check how you prepared the zero cuvette.
- Inverted Cuvettes: the sample and zero cuvettes are swapped. Swap them back and repeat.
- Under Range: a blinking "0.00" means the sample reads below the zero reference. Use the same cuvette for zero and measurement.
- Over Range: the top value blinks. Check for debris, dilute the sample and repeat.
- Battery Low or Drained Battery: replace the 1.5V AAA battery.
What nitrate should you aim for?
Sources differ. Bulk Reef Supply lists 1 to 10 ppm. Reef Builders (2008) says 10 ppm or less, and Reef Builders (2020) says near zero. The HI781 reads from 0.00 to 5.00 ppm without dilution, so it covers the low end of those ranges.
Questions people ask
How long does the Hanna nitrate checker take?
After zeroing, the countdown is 8 minutes. Before that you shake reagent B for 1 minute and reagent C for 2 minutes.
Why does the nitrate checker use a filter?
Hanna's steps pass the mixed sample through a paper filter into the cuvette. The manual says zinc powder can leave residue in the filter holder.
What is the range of the HI781?
0.00 to 5.00 ppm as NO3 with 0.01 ppm resolution, and up to 50.0 ppm calculated if you dilute. Accuracy is plus or minus 0.25 ppm plus or minus 2% of the reading at 25 C.
Can I use it on a freshwater tank?
Hanna says this test is not recommended for freshwater applications.
Gear for this job
Keep the nitrate kit parts together
The Hanna Nitrate Checker Kit Organizer is a 3D-printed holder for the Hanna Instruments Nitrate Checker kit, made to store its components. CuveDry holds Hanna Checker cuvettes upright to air dry.
Shop Hanna checker organizersKeep reading: Reef Tank Parameters: The Numbers to Test and Target · Reef Tank Maintenance Schedule: Daily, Weekly, Monthly
Sources
- Hanna Instruments: HI781 Marine Nitrate Low Range instruction manual (IST781 09/20)
- Hanna Instruments: Marine Nitrate Low Range Checker HC, HI781
- Reef Builders: Important Water Parameters For Keeping A Saltwater Aquarium (2020)
- Reef Builders: Stable Reef water parameters make a successful reef (2008)
- Bulk Reef Supply: A Weekly Saltwater Aquarium Maintenance Checklist